Data Center Connectivity & Upstream
Our center is serviced by Multiple Global carriers including Level 3,FiberLight, AT&T, TW Telecom, Verizon Business, Florida Power & Light FiberNet, Global Crossing, Qwest, , Bellsouth, Savvis, and XO. With these carrier choices at your fingertips you'll be allowed greater flexibility in designing your dedicated file server and co location needs. Our technical assistance team can establish cross connects in an industry-best turnaround time of less than 24 hours. |
Facility Security and Environmental Information:
The data center is attended 24 hours a day 365 days a year with security officers who control access to the building and key card access to the elevators for customers with valid picture identification only. Additional multi-level physical security measures are in place to provide a maximum of protection - the highest in the industry. The raised floor and individual cage and cabinet areas are guarded with Biometric hand readers add incremental protection and Client access is limited to only their rack space, accessible via a combination code. The racks are designed so that each client can only access their specific rack location. The interior layout of each rack will not allow access to other client's racks from the inside.
All activities in and around the center are captured with CCTV digital cameras and recorders monitor, record, and archive data future retrieval. The CCTV is also fully integrated with the alarm system. The building's structural design surpasses all local building codes and standards with added security measures.
The facility is protected by the TotalPac Fire Suppression System. This system is a dual alarmed, dual interlock, multi-zoned, pre-zoned, pre-action, dry pipe fire suppression delivery system. The electrical and mechanical systems have been built with the latest technologies that provide clients with N+1 redundancy to guarantee continuous operation with branch breaker monitoring and dual power grid services.
Management and monitoring of all environmental systems is continuous with 24 hour, 365-day electronic detection systems. Our raised floor environment, and 14' high ceilings ensure that your equipment is maintained with N+1 cooling for optimum airflow and humidity at 72oF. Power systems are designed for maximum effectiveness and are capable for delivering 120v, 208v, 480v AC, and -48v DC to match each client's specific needs.
|
Product & Service Offerings
We are very proud to offer a wide range of service and product offerings to fit a wide variety of business needs – for small to large corporations – USA, Latin America, and Europe. Some of our most popular services include:
DataCenter Specifications:
- Co location Cabinets: Available in Full, Half, and Quarter Racks Sizes with a choice in Amp and Bandwidths – Featuring Disaster Recovery, Network Redundancy, Regulatory Compliance, Technical Support, and 99.99% guaranteed levels of service.
- Backup Services: HOP Networks uses a secure, offsite location which is readily available should the need arise. .
- Dedicated Servers: Before your business is set up with a dedicated server, HOP Networks evaluates your current business needs and then customizes a dedicated server solution – the recommended solution is configured with the appropriate software, processor, hard drive space, speed, services, number of IP's, and backup services to fit your business needs. As your business grows, we can help you add features and services to your dedicated server solution to fit your growing needs.
- Location: 36 NE 2nd St., Miami, FL 33132 – 3rd & 4th Floor + Roof; 48,000 sq ft. floor plates
- Building: Built in 1925. Renovated in 2009 to telecom standards
- Roof: Four ply built-up roof (1999), rated to 150 mph
- AC/DC Power: 120v, 208v, 480v AC and -48 DC – underground feed served by three substations
- Global Carriers: Fiberlight, AT&T, TW Telecom, Verizon Business, Level 3, Global Crossing, Quest, Florida Power & Light FiberNet, BellSouth, Savvis, and XO, Direct Connect Internet Access
- Floor Height: 14' deck to deck with no obstructions and featuring a raised floor environment
- Redundancy: AC/DC UPS Power
- Air Conditioners: (8) 20 Ton Air Conditioners service each floor – 72oF humidity/temperature
- Security: CCTV digital cameras and recorders, alarm system, biometric hand readers, plus key cards. 24/7/365 security staff; TotalPac – fire suppression system. Mission "Hospital Priority" in Florida Power and Light (utility power) Critical Power hierarchy
- Rack Space: Accessible only by combination – racks built so that each unit is completely Non-accessible by other clients that may share rack space in the nearby area.
- Antenna Towers: Existing 100' and 65' towers available for client use
- Diverse conduit Entry Points: Two (2) manhole entries each East and West (four total entry points)
- Diverse Basement Entries: Ten (10) 4" conduits installed between the basement entries and the manholes for client use.
- Separate Power Riser: Power risers from basement to rooftop with walk-in catwalk on each floor
- Separate Wet Riser: Dedicated wet riser for HVAC systems
- Loading Dock: two bays with access to freight elevator
- Freight Elevator: 96" x 120" door, 120" x 120" x 60" cab
- Freight Elevator: 5,000 lbs capacity
|